Trueness and precision of facial scan and virtual patient representation workflow.


ABSTRACT:

Purpose

To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR).

Materials and methods

One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB). Thirteen adhesive markers were added to the face as an extraoral scan body (ESB). Two facial scans were obtained for each VPR using an infra-red laser accessory sensor (Structure sensor; Occipital Inc) mounted on a computer tablet (iPad Pro; Apple Inc), including one with seated ISB and one without ISB. Two maxillary intraoral scans were obtained using an intraoral scanner (Omnicam; Dentsply Sirona) with and without the ISB. All files were imported to a dental software program