Ontology highlight
ABSTRACT: Background
Paravalvular leak (PVL) remains a frequent complication of transcatheter aortic valve replacement (TAVR). The long-term consequences of mild PVL on outcomes have been debated. This study aimed to investigate the clinical and hemodynamic outcomes of mild PVL over a 2-year period.Methods
We conducted a retrospective cohort study of 2601 adult patients who underwent TAVR at the Cleveland Clinic between January 2016 and July 2021. Patients were categorized based on postprocedural PVL severity (mild vs. no/trace PVL). Differences in 2-year clinical outcomes, including all-cause mortality and heart failure hospitalizations, were assessed using Cox regression analysis, while hemodynamic changes were analyzed with a linear mixed model.Results
Mild PVL was present
SUBMITTER: Rosenzveig A
PROVIDER: S-EPMC12395174 | biostudies-literature | 2025 Sep
REPOSITORIES: biostudies-literature