ABSTRACT: Purpose
The reliability of a new academic software, PET KinetiX, designed for fast parametric 4D-PET imaging computation, is assessed under simulated conditions.Methods
4D-PET data were simulated using the XCAT digital phantom and realistic time-activity curves (ground truth). Four hundred analytical simulations were reconstructed using CASToR, an open-source software for tomographic reconstruction, replicating the clinical characteristics of two available PET systems with short and long axial fields of view (SAFOV and LAFOV). A total of 2,800 Patlak and 2TCM kinetic parametric maps of 18F-FDG were generated using PET KinetiX. The mean biases and standard deviations of the kinetic parametric maps were computed for each tissue label and compared to the biases of u