Drum rolling resistance consistently predicts SmartWheel rolling resistance and resultant force for manual wheelchair wheels and casters.
Ontology highlight
ABSTRACT: Introduction: Minimizing repetitive strain (RS) is a key recommendation from clinical practice guidelines for preservation of upper limb. Propulsion force, which is required to overcome wheel rolling resistance (RR), is a major source of RS. A drum-based RR test method has been developed but has not been directly validated against propulsion forces. A previous validation study compared Drum versus treadmill RR, with excellent consistency (intraclass correlation coefficient (ICC) = 0.94) and accuracy. Methods: Drum RR system estimates (N = 192) were compared to SmartWheel RR measurements and resultant force (Fres) for multiple wheelchair setups and surfaces. We hypothesized that Drum RR will consistently predict SmartWheel RR and Fres based on ICC and accuracy based on Bland A
SUBMITTER: Wilson-Jene H
PROVIDER: S-EPMC12409041 | biostudies-literature | 2025 Jan-Dec
REPOSITORIES: biostudies-literature
ACCESS DATA