ABSTRACT: Background
Despite the Coronary Artery Reporting and Data System (CAD-RADS) providing a standardized approach, radiologists continue to favor free-text reports. This preference creates significant challenges for data extraction and analysis in longitudinal studies, potentially limiting large-scale research and quality assessment initiatives.Objective
To evaluate the ability of the generative pre-trained transformer (GPT)-4o model to convert real-world coronary computed tomography angiography (CCTA) free-text reports into structured data and automatically identify CAD-RADS categories and P categories.Methods
This retrospective study analyzed CCTA reports from January 2024 and July 2024. A subset of 25 reports was used for prompt engineering to instruct the large language models (LLMs) in extracting CAD-RADS categories, P categories, and the presence of myocardial bridges and noncalcified plaques. Reports were processed using the GPT-4o API (application programming interface) and custom Python scripts. The ground truth was established by radiologists based on the CAD-RADS 2.0 guidelines. Model performance was assessed using accuracy, sensitivity, specificity, and F1-score. Intrarater reliability was assessed using Cohen κ coefficient.Results
Among 999 patients (median age 66 y, range 58-74; 650 males), CAD-RADS categorization showed accuracy of 0.98-1.00 (95% CI 0.9730-1.0000), sensitivity of 0.95-1.00 (95% CI 0.9191-1.0000), specificity of 0.98-1.00 (95% CI 0.9669-1.0000), and F1-score of 0.96-1.00 (95% CI 0.9253-1.0000). P categories demonstrated accuracy of 0.97-1.00 (95% CI 0.9569-0.9990), sensitivity from 0.90 to 1.00 (95% CI 0.8085-1.0000), specificity from 0.97 to 1.00 (95% CI 0.9533-1.0000), and F1-score from 0.91 to 0.99 (95% CI 0.8377-0.9967). Myocardial bridge detection achieved an accuracy of 0.98 (95% CI 0.9680-0.9870), and noncalcified coronary plaques detection showed an accuracy of 0.98 (95% CI 0.9680-0.9870). Cohen κ values for all classifications exceeded 0.98.Conclusions
The GPT-4o model efficiently and accurately converts CCTA free-text reports into structured data, excelling in CAD-RADS classification, plaque burden assessment, and detection of myocardial bridges and calcified plaques.
SUBMITTER: Chen Y
PROVIDER: S-EPMC12422720 | biostudies-literature | 2025 Sep
REPOSITORIES: biostudies-literature

JMIR medical informatics 20250910
<h4>Background</h4>Despite the Coronary Artery Reporting and Data System (CAD-RADS) providing a standardized approach, radiologists continue to favor free-text reports. This preference creates significant challenges for data extraction and analysis in longitudinal studies, potentially limiting large-scale research and quality assessment initiatives.<h4>Objective</h4>To evaluate the ability of the generative pre-trained transformer (GPT)-4o model to convert real-world coronary computed tomography ...[more]