Ontology highlight
ABSTRACT: Background
Mechanical heart valves offer long-term durability but carry a risk of thrombosis, even with therapeutic anticoagulation.Case summary
We present a case of a patient with a history of Bentall procedure and bovine aortic arch who developed a thrombotic stuck mechanical aortic valve. Despite therapeutic international normalized ratio and administration of thrombolytics, the obstruction persisted. Given the patient's high surgical risk, a novel percutaneous interventional approach was used, resulting in restoration of valve function and a favorable clinical outcome.Discussion
Mechanical valve thrombosis is a rare but life-threatening condition with an incidence of 0.1% to 5.7%. Although subtherapeutic international normalized ratio is a common cause, cases ma
SUBMITTER: Ahmed Almusawi AH
PROVIDER: S-EPMC12426551 | biostudies-literature | 2025 Aug
REPOSITORIES: biostudies-literature