ABSTRACT: Background
Subcutaneous implantable cardioverter-defibrillator (S-ICD) infection can be managed conservatively, shifting the generator from the submuscular to intermuscular pocket.Case summary
A 50-year-old man with hypertrophic cardiomyopathy and an S-ICD implanted as primary prevention with the intermuscular pocket technique was admitted to the cardiology department for a check-up owing to evidence of a pseudonodular skin lesion over the catheter sleeve that developed after having shaved the chest. Positron emission tomography/computed tomography scan was performed and revealed an active infection both over the S-ICD generator and along the lead. The patient declined transvenous ICD reimplantation, so we performed a revised shift and cover technique, shifting the pocket f