Unknown

Dataset Information

Flow cytometry protocol for cell death analysis in glioblastoma organoids: A technical note.


ABSTRACT: Tumor organoid models have emerged as a promising tool in cancer research. By preserving intra- and intertumoral heterogeneity and structural integrity they provide a physiologically relevant platform for drug-response studies. However, valid methodological approaches for cell death analyses applying flow cytometry, particularly in complex, large organoids, are lacking. Using glioblastoma organoids (GBOs), we developed a flow cytometry protocol to quantify cell death as an important readout in cancer research. Human GBOs were generated out of tumor material from six patients. Temozolomide (TMZ) and lomustine (CCNU) were used as cytotoxic agents commonly employed in glioblastoma therapy. After treatment for 144 and 288 hours, single cell suspensions from densely-packed GBOs were generated t

SUBMITTER: Potthoff AL 

PROVIDER: S-EPMC12456761 | biostudies-literature | 2025

REPOSITORIES: biostudies-literature