Unknown

Dataset Information

0

Strain-Sensitive Thermochromic Smart Electronic Skin for Joint and Spine Healthcare Applications.


ABSTRACT: Electronic skins (E-skins) that enable interactive and quantitative joint and spine healthcare hold transformative potential for personalized musculoskeletal rehabilitation. However, existing systems face three critical limitations: conventional strain sensors degrade with cyclic large strain due to uncontrolled crack propagation; thermal therapy lacks real-time adaptive control without feedback; and systems lack user-interactive monitoring-therapy integration. Here, iStretch, a mechano-visual-thermo adaptive e-skin is introduced that integrates durable strain sensing, dynamic heat therapy, and intuitive visual feedback via a multiphasic and bilayer architecture. The strain-sensing bottom layer utilises constrained microcrack propagation in graphene-liquid metal nanocomposites, achieving high sensitivity (GF = 281), broad sensing range (300%), and exceptional durability (10,000 cycles). Simultaneously, the thermoresponsive top layer provides dynamic visual feedback and heat modulation in response to strain. Its multifunctions are demonstrated for convolutional neural network-powered omnidirectional motion and gesture recognition, strain magnitude-adjusted thermotherapy, intuitive thermochromic overheating alerts, and quantitative cervical spine monitoring via wireless sensor arrays.

SUBMITTER: Fan S 

PROVIDER: S-EPMC12499495 | biostudies-literature | 2025 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Strain-Sensitive Thermochromic Smart Electronic Skin for Joint and Spine Healthcare Applications.

Fan Shicheng S   Chen Shuwen S   Qiao Zheng Z   Qi Jiaming J   Wu Zixiong Z   Lim Chwee Teck CT  

Advanced science (Weinheim, Baden-Wurttemberg, Germany) 20250706 37


Electronic skins (E-skins) that enable interactive and quantitative joint and spine healthcare hold transformative potential for personalized musculoskeletal rehabilitation. However, existing systems face three critical limitations: conventional strain sensors degrade with cyclic large strain due to uncontrolled crack propagation; thermal therapy lacks real-time adaptive control without feedback; and systems lack user-interactive monitoring-therapy integration. Here, iStretch, a mechano-visual-t  ...[more]

Similar Datasets

| S-EPMC7507701 | biostudies-literature
| S-EPMC6941885 | biostudies-literature
| S-EPMC9108621 | biostudies-literature
| S-EPMC9105753 | biostudies-literature
| S-EPMC10827790 | biostudies-literature
| S-EPMC11548264 | biostudies-literature