Pressure Sensing and Kinetic Modeling of Oxygen-Releasing Endoperoxides for Chemically Driven Micro-Actuation.
Ontology highlight
ABSTRACT: This work presents a pressure-based sensing framework to directly track and monitor oxygen release from anthracene-endoperoxide (ANT-EPO) decomposition in an aqueous environment. ANT-EPO shows potential as an on-demand gas source for applications in pneumatic actuators and soft robotics. However, its integration into functional systems requires accurate, real-time characterization of oxygen release kinetics. To address this, a sealed measurement chamber coupled with a calibrated low-pressure sensor was employed to enable long-term, continuous tracking of oxygen release under ambient conditions (37 °C) and at room temperature. A multistep signal processing pipeline was implemented to extract meaningful kinetic information from the pressure response resulting from oxygen release. The raw pre
SUBMITTER: Sharma A
PROVIDER: S-EPMC12508970 | biostudies-literature | 2025 Oct
REPOSITORIES: biostudies-literature