ABSTRACT:

Background

Need for permanent pacemaker implantation (PPI) following transcatheter aortic valve replacement (TAVR) remains a common complication. We aimed to assess computed tomography (CT)-based anatomical and electrocardiogram (ECG)-based parameters in a predictive model for PPI following TAVR.

Methods

We assessed CT-based parameters, including the predicted course of the conduction axis from atrioventricular node to left bundle branch origin relative to the aortic virtual basal ring. Electrophysiological variables were combined in assessing a model to predict post-TAVR PPI.

Results

Among 433 patients (mean age 82.0 [9.0] years, 54.0% female), 90 (21.0%) required PPI. Multiple binary logistic modeling demonstrated a shallower position of the membranous septum inferi

SUBMITTER: Tretter JT 

PROVIDER: S-EPMC12516544 | biostudies-literature | 2025 Nov