Ontology highlight
ABSTRACT: Background
Dual lumen microcatheters are required to navigate angulated and diseased side branch. Many a times, they are not available.Case summary
We used an alternative inexpensive pierced-balloon technique to manoeuver coronary wire across a diseased and angulated left circumflex artery in a case of distal critical bifurcation disease of the left main coronary artery in a 57-year-old gentleman who presented with non-ST elevation myocardial infarction.Discussion
This technique can be used as an alternative to double lumen microcatheter when the latter is unavailable. It is inexpensive and a regular balloon catheter albeit of longer length needs to be used.
SUBMITTER: Nanjappa V
PROVIDER: S-EPMC12530352 | biostudies-literature | 2025 Oct