Inter-rater agreement of HER2-low scores between expert breast pathologists and the Visiopharm digital image analysis application (HER2 APP, CE2797).


ABSTRACT: Inter-observer concordance data for the HER2 category as assessed by a group of 16 specialist breast pathologists on 50 diagnostic core biopsies was compared with that produced by digital image analysis (DIA) using the HER2 APP, CE2797 (VP APP; Visiopharm, Hoersholm, Denmark). Comparing pathologists' consensus scores and DIA scores, 36 cases (73.5%) agreed. Fleiss' kappa statistic was 0.433 (indicative of moderate agreement). Cohen's weighted kappa was used to compare the scores of individual raters to consensus scores; for all 50 cases the kappa scores had a range between 0.412 and 0.854; the VP APP was ranked 12th of 17 raters (kappa score 0.638 indicating substantial agreement). Results for HER2-low cases (N = 44) showed a kappa score range of 0.295 to 0.823; the VP APP ranked 12th of 1

SUBMITTER: Parry S 

PROVIDER: S-EPMC12531420 | biostudies-literature | 2025 Nov