Infection following inflatable penile prosthesis placement: a real-world comparison of device selection and patient characteristics.


ABSTRACT:

Background

Advancements in device design have reduced infectious complications following inflatable penile prosthesis (IPP) implantation. This study evaluated infection rates among two models of IPP devices available in the United States, AMS 700™ and Titan®, using real-world data.

Methods

Patients aged ≥18 years from the Premier PINC AI™ Healthcare Database who underwent IPP insertion with either AMS 700 or Titan between 2016 and 2022 were included. Twelve published risk factors for IPP infection [age >75 years, smoking, human immunodeficiency virus (HIV), diabetes, pelvic radiation, urinary diversion, spinal cord injury, obesity, concomitant circumcision, and Peyronie's disease] were used to characterize patients. The association between device model and infecti

SUBMITTER: Nguyen V 

PROVIDER: S-EPMC12541495 | biostudies-literature | 2025 Sep