Unknown

Dataset Information

0

A Printable OECT for Simple Integration in Nitrocellulose-Based Assays.


ABSTRACT: Paper-based biosensors hold significant promise for point-of-care (POC) diagnostic applications. Among these, lateral flow assays (LFAs) are particularly appealing due to their ease of use, portability, and low cost. However, their limited sensitivity and qualitative output set drawbacks on their reliability and widespread application. In response to the growing need for rapid and consistent diagnostic and monitoring tools, Organic Electrochemical Transistors (OECTs) have emerged as powerful devices in biochemical sensing applications because of their high sensitivity, low operating voltage, and compatibility with a biological environment. In this work, we developed a printable OECT for biochemical sensing on a commercial cellulose membrane, commonly used as a detection substrate in LFA-based rapid tests. Constituting a self-standing, passive microfluidic platform, the system was designed to transport and interact with liquid samples, while ensuring a contamination-free zone for the active components. Inside a dry area delimited by a hydrophobic barrier, the OECT components include dispense-printed silver electrodes, a polystyrenesulfonate-doped poly(3,4-ethylenedioxy-thiophene) (PEDOT:PSS) channel and gate, and a solid-state electrolyte (SSE) layer. Outside the dry area, a PEDOT:PSS extended gate alone interacts with the analyte in the liquid sample, preventing channel contamination and enhancing the system stability. We investigated the effect of dopamine (DA) oxidation at the extended gate interface on the device response and observed variations in the transfer characteristics, transconductance and Ion/Ioff ratio, obtaining a limit of detection of 0.01 mM. With a maximum transconductance of approximately 4 mS, our system shows potential for the integration of an easy-to-fabricate device into an affordable biochemical assay, providing quantitative results at the point-of-care site to complement and reinforce the typical colorimetric response of LFAs.

SUBMITTER: Cicolini M 

PROVIDER: S-EPMC12560127 | biostudies-literature | 2025 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Printable OECT for Simple Integration in Nitrocellulose-Based Assays.

Cicolini Martina M   Solgi Ali A   Vigna Lorenzo L   Ballesio Alberto A   Marasso Simone S   Cocuzza Matteo M   Kleemann Hans H   Frascella Francesca F   Napione Lucia L  

ACS sensors 20250930 10


Paper-based biosensors hold significant promise for point-of-care (POC) diagnostic applications. Among these, lateral flow assays (LFAs) are particularly appealing due to their ease of use, portability, and low cost. However, their limited sensitivity and qualitative output set drawbacks on their reliability and widespread application. In response to the growing need for rapid and consistent diagnostic and monitoring tools, Organic Electrochemical Transistors (OECTs) have emerged as powerful dev  ...[more]

Similar Datasets

| S-EPMC12582273 | biostudies-literature
| S-EPMC10102301 | biostudies-literature
| S-EPMC12850065 | biostudies-literature
| S-EPMC11463256 | biostudies-literature
| S-EPMC7497792 | biostudies-literature
| S-EPMC6160485 | biostudies-literature
| S-EPMC2869488 | biostudies-literature
| S-EPMC11757229 | biostudies-literature
| S-EPMC9098115 | biostudies-literature