Unknown

Dataset Information

A Reliable and Simple Voltammetric Method for Analysis of Brilliant Blue FCF.


ABSTRACT: Synthetic food colourings are widely used because they are stable, inexpensive, reliable, and effective in shaping consumer perception and behaviour, even though some are under scrutiny for adverse health effects. In this work, we present a new sensitive voltammetric method for the determination of brilliant blue FCF (BB) using a cyclic renewable silver-based mercury film electrode (Hg(Ag)FE). The experimental parameters, including pulse height, step potential, preconcentration potential and duration, and the composition of the supporting electrolyte, were systematically optimised. Under these conditions, the calibration curve exhibited linearity within the range of 0.7 up to 250 µg L-1. For an Hg(Ag)FE with a surface area of 10.9 mm2, with a short preconcentration st

SUBMITTER: Szlosarczyk M 

PROVIDER: S-EPMC12567795 | biostudies-literature | 2025 Oct

REPOSITORIES: biostudies-literature