Enhancing the Reliability of Chemical Evaporators: A Method for Reinforcing the Fitting Hole.


ABSTRACT: Evaporative heat exchangers often fail near the fitting hole, where heat and pressure concentrate. We evaluate a simple external-ring reinforcement that redistributes local stresses while preserving heat-transfer duty. Positioned among established reinforcement options, the approach is compared conceptually with collars and sleeves in terms of installation time, material use, and inspectability. Laboratory tests and finite-element analysis (FEA) were used together to map stress and deformation fields before and after reinforcement, and checks against ASME PTB-3-2013 design guidance confirm adequate safety margins. By redistributing load and eliminating crevice-forming gaps near the fitting, the ring removes the microconditions that foster fatigue and corrosion. Thermal performance was char

SUBMITTER: Feiler L 

PROVIDER: S-EPMC12593161 | biostudies-literature | 2025 Nov

REPOSITORIES: biostudies-literature