Effect of Additional Aluminum Filtration on the Image Quality in Cone Beam Computed Tomographic Studies of Equine Distal Limbs Using Visual Grading Characteristics Analysis: A Pilot Study.
Ontology highlight
ABSTRACT: (1) Background: Cone beam computed tomography (CBCT) is increasingly used in equine practice to diagnose musculoskeletal injuries, including fractures in the distal limb. However, limited detail in the thick cortical bone of the metacarpus/metatarsus hinders accurate diagnosis. In human medicine, the addition of aluminum filters (AF) enhanced image quality while reducing radiation exposure. This study aimed to evaluate the effect of AF on image quality in CBCT scans of equine distal limbs. (2) Methods: Adult equine cadaver limbs were scanned with a mobile CBCT unit using varying tube currents (10-100 mA) and AF (13-25 mm). Two independent experts assessed the image quality using a four-point visual grading scale, focusing on cortical bone detail and artifacts. (3) Results: Higher tube curr