Ontology highlight
ABSTRACT: Background
Automatic office blood pressure measurement (AOBPM) in the waiting room could improve the performance of diagnosing hypertension without requiring an isolated room to carry out exploration.Methods
In a cross-sectional study, we compared the performance to diagnose and phenotyping hypertension by 3 methods of blood pressure measurements, standard office blood pressure, unattended AOBPM in an isolated room or in an office waiting room AOBPM, compared with daytime ambulatory blood pressure measurement (daytime ambulatory blood pressure monitoring) from a 24-hour ambulatory blood pressure monitoring as a reference. The cutoff values for hypertension and validation for waiting room or isolated room AOBPM were performed by receiver operating characteristic curves and B
SUBMITTER: Sanchez Bacaicoa M
PROVIDER: S-EPMC12684479 | biostudies-literature | 2025 Oct
REPOSITORIES: biostudies-literature