ABSTRACT: Introduction
Pedicle screw fixation in osteoporotic spines remains challenging. Bazedoxifene (BZA) and denosumab (Dmab) are widely used agents for osteoporosis, but their comparative effects on spinal instrumentation are not well understood. This study aimed to evaluate the effects of BZA and Dmab on biomechanical parameters of spinal instrumentation using finite element analysis (FEA).Methods
In this prospective, open-label study, postmenopausal women with primary osteoporosis were assigned to receive either BZA (daily oral, 20 mg) or Dmab (subcutaneous, 60 mg every 6 months) for 12 months. FEA models of the L4 vertebra were generated from CT scans using a calibration phantom (Mindways, Austin, TX, USA). Vertebral compression force was evaluated to represent overall verteb