Unknown

Dataset Information

Using dP/dt Contour Analysis to Wean IABP/Inotropic Support in a Cardiogenic Shock Patient.


ABSTRACT:

Background

dP/dt, the rate of ventricular pressure rise during systole, reflects myocardial contractility and is traditionally measured invasively or by echocardiography. New technologies derive it from real-time peripheral arterial waveforms, offering a minimally invasive surrogate, though intensive care unit use remains limited because of preload/afterload sensitivity and minimal investigative studies.

Summary

We report, to our knowledge, the first clinical case using continuous arterial dP/dt pressure waveform analysis (PWA) in the intensive care unit to guide real-time management in cardiovascular (CV) assessment of a patient with Society for Cardiovascular Angiography and Interventions (SCAI) stage E cardiogenic shock.

Discussion

As illustrated in our patient, dP

SUBMITTER: Kapadia KN 

PROVIDER: S-EPMC12714517 | biostudies-literature | 2025 Nov

REPOSITORIES: biostudies-literature