Reducing breast biopsy at MRI: comparison of minimum ADC cutoff and mean ADC cutoff identified by the ECOG-ACRIN A6702 multicenter trial.


ABSTRACT:

Background

The aim of this study was to validate the generalisability of the ECOG-ACRIN A6702 multicenter trial identified mean apparent diffusion coefficient (ADC) cutoff (1.53 × 10- 3mm2/s) and compare its biopsy reduction efficacy against a data-derived ADC minimum (ADCmin) cutoff.

Methods

This dual-cohort retrospective analysis included 453 patients with 494 BI-RADS 4/5 lesions (derivation cohort: 288 patients/311 lesions; validation: 165 patients/183 lesions). ADCmin and mean ADC (ADCmean) were measured, the data-derived ADCmin cutoff was optimised via an ROC analysis (negative likelihood ratio ≤ 0.1) .Performance metrics included biopsy reduction rates, sensitivity, and false-negative rates, stratified b