Unknown

Dataset Information

Optimizing lung SBRT delivery: A hybrid approach combining dynamic conformal arc (DCA) and volumetric modulated arc therapy (VMAT) techniques.


ABSTRACT:

Purpose

This study introduces and evaluates a hybrid dynamic conformal arc-volumetric modulated arc therapy (hDCA-VMAT) technique for lung stereotactic body radiotherapy (SBRT). The goal is to combine the planning efficiency of VMAT with the delivery robustness of dynamic conformal arc (DCA) techniques, particularly for low-density lung targets where motion and dose calculation uncertainties pose challenges.

Methods

Twenty-four previously treated lung SBRT cases were retrospectively replanned using hDCA-VMAT, conventional VMAT, and aperture controlled VMAT (VMAT_AC). hDCA-VMAT plans were initiated with a manually created DCA plan, followed by limited inverse optimization with constrained aperture modulation. Plans were created in Eclipse v16.1 and calculated using the Acuros

SUBMITTER: Snyder KC 

PROVIDER: S-EPMC12795709 | biostudies-literature | 2025 Sep