Biomechanical optimization of iliolumbar fixation strategies for unilateral vertical sacral fractures: Prioritizing stability-mobility balance via finite element analysis.


ABSTRACT:

Objective

This study aims to optimize iliolumbar fixation strategies for unilateral vertical sacral fractures via finite element analysis, by comparing stability, implant stress, and lumbar mobility to identify the optimal clinical option.

Methods

A finite element model of the pelvis and L3-L5 lumbar spine was constructed to simulate four fixation models (L4L5IS, L5S1IS, L5IS, S1IS) under a 600 N vertical load. Sacral vertical displacement, implant stress, and fracture line separation were analyzed.

Results

Double-segment fixation (L4 + L5 + iliac screw and L5 + S1 + iliac screw) demonstrated superior sacral stability compared to single-segment fixation (L5 + iliac screw and S1 + iliac screw). The L5 + S1 + iliac screw configuration achieved the best balance of stabil

SUBMITTER: Ma Y 

PROVIDER: S-EPMC12798994 | biostudies-literature | 2026