Unknown

Dataset Information

Hybrid Pulmonary Valve Replacement in Very Large Right Ventricular Outflow Tract Using a Self-Expanding Valve.


ABSTRACT:

Background

Patients with very large right ventricular outflow tract (RVOT) may not be suitable for percutaneous pulmonary valve implantation (PPVI). Hybrid PPVI, combining surgical pulmonary artery plication with transcatheter valve implantation, may offer a feasible alternative to surgical valve replacement for high-risk patients.

Case summary

We report the first hybrid PPVI using the Venus P-Valve (Venus Medtech) in a 60-year-old man with very large RVOT and severe biventricular dysfunction, as well as his follow-up at 5 months.

Discussion

This case demonstrates the feasibility of hybrid PPVI with pulmonary artery plication and a self-expanding valve in patients with very large RVOT.

Take-home message

Hybrid PPVI using a self-expanding valve is a feasible app