Unknown

Dataset Information

Time-resolved imaging of electron beam powder bed fusion using an X-ray microscope optimized for white beam radiation.


ABSTRACT: A high-speed synchrotron radiography system has been developed to facilitate in situ imaging of dynamic processes in electron beam powder bed fusion (PBF-EB). Using the P61A White Beam Engineering Materials Science beamline at PETRA III, this system achieves high temporal resolution and a spatial resolution of approximately 10 µm. The scintillator screens are coupled to a diamond plate and housed within a specialized nitrogen gas cooling system, effectively mitigating thermal stress caused by the intense synchrotron beam. These innovative components ensure stable imaging performance and enhance the system's ability to operate under extreme conditions. By resolving fringes at short propagation distances for the partially coherent beam, the imaging system has enabled the efficient visualizat

SUBMITTER: Bidola P 

PROVIDER: S-EPMC12809454 | biostudies-literature | 2026 Jan

REPOSITORIES: biostudies-literature