Diagnostic accuracy of real‑time point-of-care tracheal ultrasonography for the confirmation of proper endotracheal tube placement in neonatal acute care settings: a systematic review and diagnostic test accuracy meta-analysis.
Ontology highlight
ABSTRACT: Accurate confirmation of endotracheal tube (ETT) placement is critical in neonatal resuscitation. This systematic review and meta-analysis assessed the diagnostic accuracy of point-of-care ultrasound (POCUS) for confirming ETT placement in neonates. We searched PubMed, Scopus, Web of Science, and Cochrane Library through May 2025. Eligible studies included neonates (<28 days) and compared POCUS with gold-standard confirmation (capnography, chest radiography, or direct laryngoscopy). Diagnostic performance was pooled using a bivariate random-effects model. Thirteen studies (930 neonates) met inclusion criteria. POCUS showed pooled sensitivity of 93% and specificity of 59%, with an area under the SROC curve of 92%. tracheal placement was confirmed in 99%, and esophageal misplacement detected
SUBMITTER: Alsabri M
PROVIDER: S-EPMC12815668 | biostudies-literature | 2026 Jan
REPOSITORIES: biostudies-literature
ACCESS DATA