Clinical utility of a novel double-band endoscopic band ligation device for consecutive ligation in the management of diverticular bleeding.


ABSTRACT:

Background and aims

Endoscopic band ligation is effective for diverticular bleeding; however, conventional devices have drawbacks such as limited visibility, weak suction, and single-use design. Endoligar (Asahi Intecc Co Ltd, Aichi, Japan) addresses these limitations with clear visibility, strong suction, and the ability to perform 2 ligations without removing the endoscope. This report evaluates its clinical utility.

Methods

An 82-year-old man with a history of diverticular bleeding was admitted for hematochezia lasting 3 days. Noncontrast computed tomography and emergency colonoscopy suggested a bleeding diverticulum in the ascending colon. A diverticulum at the hepatic flexure showed signs of a recent hemorrhage, but no active bleeding; a clip was placed for marking. On