ABSTRACT: Objective
To evaluate the diagnostic value of the combined detection of cryptococcal antigen (CrAg) in the serum and lung puncture fluid (LPF) using a lateral flow assay (LFA) in patients with pulmonary cryptococcosis (PC).Methods
Patients with suspected PC were prospectively enrolled between June 2023 and July 2025 and underwent the IMMY CrAg LFA (Immuno-Mycologics, Norman, OK, United States) of serum and LPF specimens. Conventional fungal cultures were performed simultaneously and the diagnostic efficiencies of these methods for PC were compared.Results
Samples were obtained from 167 patients, 33 with PC and 134 without PC. Among patients with PC, the sensitivity of serum CrAg testing was 75.8% [95% confidence interval (CI), 61.1-90.4%; 25/33] and that of LPF CrAg