Ontology highlight
ABSTRACT: Background
Stent dislodgement with systemic embolization is a rare but serious complication of percutaneous coronary intervention.Case summary
During intravascular ultrasound-guided percutaneous coronary intervention for aorto-ostial left main artery stenosis, a fully expanded 4.0-mm drug-eluting stent dislodged upon balloon withdrawal. Angiography showed the stent partially floating in the aortic root, with its distal struts still anchored at the ostium, before its complete embolization. After securing the left main artery with a second stent, the dislodged stent was identified following systemic embolization to the left renal artery. Given the high risk of retrieval, it was managed in situ with balloon expansion to achieve full apposition against the vessel wall.Discu
SUBMITTER: Hendrianus
PROVIDER: S-EPMC12905722 | biostudies-literature | 2026 Feb