Ontology highlight
ABSTRACT: Background
In the assessment of coronary physiology, non-hyperemic pressure ratios (NHPRs) provide an alternative to fractional flow reserve (FFR) without the need for hyperemic agents, reducing procedural time, side effects, and costs. However, it remains unclear whether NHPRs have similar diagnostic performance in the different coronary arteries. This study evaluates the diagnostic performance of NHPRs compared with FFR, stratified by coronary artery, in stable patients with coronary artery disease.Methods
We conducted a systematic review and individual patient-level data meta-analysis from prospective studies involving patients with intermediate to severe coronary stenosis who underwent physiological assessment with NHPRs and FFR. NHPRs included resting full-cycle ratio
SUBMITTER: Storozhenko T
PROVIDER: S-EPMC12919497 | biostudies-literature | 2026 Jan
REPOSITORIES: biostudies-literature