ABSTRACT: Rationale and objectives
Hyperpolarized xenon-129 (129Xe) MRI is an established, sensitive method to assess ventilation but lacks a standardized ventilation defect quantification. We introduce mean-anchored generalized linear binning (MeanGLB, GLB) to calculate ventilation defect percentage (VDP), benchmarking its performance against reader-segmented VDP (Reader) and five widely-used automated VDP calculation methods.Materials and methods
129Xe images were acquired from 38 people with cystic fibrosis (CF) and 25 age-matched healthy controls (HCs) using 2D-spiral sequence. Flexible chest coil-induced inhomogeneities were mitigated using both N4- or a flip-angle (FA)-based bias correction. VDP was quantified using Reader, Hierarchical and Adap