Ontology highlight
ABSTRACT: Background
Wiring in bifurcation percutaneous coronary intervention can be limited by severe angulation, adverse plaque biasing, and ostial ambiguity. Real-time intravascular ultrasound (RT-IVUS) guidance can augment wire manipulation when standard techniques fail.Case summary
A 49-year-old man with exertional angina had a critical lesion left anterior descending (LAD)-2nd diagonal bifurcation lesion (Medina 1,1,0) with TIMI 2 flow. Standard wiring (acutely angled wires, dual lumen, and angled microcatheters) repeatedly biased into the diagonal. Under RT-IVUS, the wire was redirected into the true lumen of mid-LAD, enabling lesion crossing, pre-dilatation, and implantation of a 3.5 × 26 mm2 DES with post-dilatation. Final IVUS showed optimal expansion (MSA 9 mm
SUBMITTER: Mohan Singh Sindhi R
PROVIDER: S-EPMC12933685 | biostudies-literature | 2026 Feb
REPOSITORIES: biostudies-literature