Optimizing cyclopean stimuli for the evaluation of stereo vision by steady-state visual evoked potentials.


ABSTRACT:

Purpose

This study aimed to optimize dynamic random dot correlogram (DRDC) and stereogram (DRDS) stimuli to evoke steady-state visual evoked potentials (ssVEP) on multiple EEG channels for the objective assessment of stereopsis.

Methods

EEG recordings were conducted on 22 healthy adults (mean age: 30.2 ± 5.8 years) while viewing cyclopean and control stimuli. DRDC and DRDS were presented at three temporal frequencies (0.9375, 1.875, and 3.75 cycles per second, cps) using anaglyphic channel separation. The ssVEP responses were analyzed using T2circ statistical test to determine the most effective stimulus for eliciting significant cortical activity.

Results

DRDC at 1.875 cps evoked significant ssVEP responses in 93% of participants on at least one occipital electrode (O1, Oz, O2) and in 100% when including parietal-occipital electrodes. DRDS at similar frequencies also produced robust responses but required additional parietal electrode monitoring. Monocular control measurements confirmed that responses were stereo-specific.

Conclusions

DRDC at 1.875 cps was the most effective stimulus for objective electrophysiological assessment of stereopsis, demonstrating high reliability with minimal electrode setups. These findings support the integration of optimized ssVEP protocols into clinical assessments, particularly for non-verbal or pediatric populations.

SUBMITTER: Rado J 

PROVIDER: S-EPMC12948872 | biostudies-literature | 2026 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimizing cyclopean stimuli for the evaluation of stereo vision by steady-state visual evoked potentials.

Radó János J   Mikó-Baráth Eszter E   Hegyi Péter P   Nemes Vanda A VA   Jandó Gábor G   Buzás Péter P  

Documenta ophthalmologica. Advances in ophthalmology 20251017 1


<h4>Purpose</h4>This study aimed to optimize dynamic random dot correlogram (DRDC) and stereogram (DRDS) stimuli to evoke steady-state visual evoked potentials (ssVEP) on multiple EEG channels for the objective assessment of stereopsis.<h4>Methods</h4>EEG recordings were conducted on 22 healthy adults (mean age: 30.2 ± 5.8 years) while viewing cyclopean and control stimuli. DRDC and DRDS were presented at three temporal frequencies (0.9375, 1.875, and 3.75 cycles per second, cps) using anaglyphi  ...[more]