Evaluation of the MicroSeq system for identification of mycobacteria by 16S ribosomal DNA sequencing and its integration into a routine clinical mycobacteriology laboratory.
Ontology highlight
ABSTRACT: An evaluation of the MicroSeq 500 microbial identification system by nucleic acid sequencing and the Mayo Clinic experience with its integration into a routine clinical laboratory setting are described. Evaluation of the MicroSeq 500 microbial identification system was accomplished with 59 American Type Culture Collection (ATCC) strains and 328 clinical isolates of mycobacteria identified by conventional and 16S ribosomal DNA sequencing by using the MicroSeq 500 microbial identification system. Nucleic acid sequencing identified 58 of 59 (98.3%) ATCC strains to the species level or to the correct group or complex level. The identification results for 219 of 243 clinical isolates (90.1%) with a distance score of <1% were concordant with the identifications made by phenotypic methods. The re
SUBMITTER: Hall L
PROVIDER: S-EPMC153882 | biostudies-literature | 2003 Apr