ABSTRACT: Background
A single breath-hold evaluation of ventricular function would allow assessment in cases where scan time or patient tolerance is limited. Spatiotemporal acceleration techniques such as TSENSE decrease cardiovascular MR acquisition time, but standard slice summation analysis requires enough short axis slices to cover the left ventricle (LV). By reducing the number of short axis slices, incorporating long axis slices, and applying a 3D model based analysis, it may be possible to obtain accurate LV mass and volumes. We evaluated LV volume, mass and ejection fraction at 3.0 T using a 3D modeling analysis in 9 patients with a history of myocardial infarction and one healthy volunteer. Acquisition consisted of a standard short axis SSFP stack and a 15 heart-beat single breath-h