Unknown

Dataset Information

ECVAM retrospective validation of in vitro micronucleus test (MNT).


ABSTRACT: In the past decade several studies comparing the in vitro chromosome aberration test (CAT) and the in vitro micronucleus test (MNT) were performed. A high correlation was observed in each of the studies (>85%); however, no formal validation for the micronucleus in vitro assay had been carried out. Therefore, a working group was established by the European Centre for the Validation of Alternative Methods (ECVAM) to perform a retrospective validation of the existing data, in order to evaluate the validity of the in vitro MNT on the basis of the modular validation approach. The primary focus of this retrospective validation was on the evaluation of the potential of the in vitro MNT as alternative to the standard in vitro CAT. The working group evaluated, in a first step, the available publish

SUBMITTER: Corvi R 

PROVIDER: S-EPMC2441751 | biostudies-literature | 2008 Jul

REPOSITORIES: biostudies-literature