Telemetric signal-driven servocontrol of renal perfusion pressure in acute and chronic rat experiments.
Ontology highlight
ABSTRACT: The present study was designed to take advantage of telemetry data acquisition and develop an easy and reliable system to servocontrol renal perfusion pressure (RPP). Digitized pressure signals from lower abdominal aorta in rats, reflecting RPP, was obtained by a telemetry device and dynamically exported into an Excel worksheet. A computer program (LabVIEW) compared the RPP data with a preselected pressure range and drove a bidirectional syringe pump to control the inflation of a vascular occluder around the aorta above renal arteries. When RPP was higher than the preselected range, the syringe pump inflated the occluder and decreased RPP, and vice versa. If RPP was within range, there was no action. In this way, RPP was servocontrolled within the desired range. In experiments with norepin
SUBMITTER: Xia M
PROVIDER: S-EPMC2584867 | biostudies-literature | 2008 Nov
REPOSITORIES: biostudies-literature
ACCESS DATA