Cyclic voltammograms at coplanar and shallow recessed microdisk electrode arrays: guidelines for design and experiment.


ABSTRACT: Although microdisk electrode arrays (MEAs) have been extensively used for more than three decades, the existing rules do not provide an unambiguous formula for the calculation of the minimum interelectrode distance (d) necessary for steady-state current response. With the aim of formulating generally applicable guidelines for design and experiment with MEAs, cyclic voltammograms were simulated for coplanar and shallow recessed microdisk electrode arrays with various interelectrode distances and dimensionless scan rates (V). The dimensionless scan rate (V) is a function of the radius (a) of the individual electrodes in the array, the diffusion coefficient (D) of the analyte, and the potential scan rate (v). The cyclic voltammograms at microdisk electrode arrays are grouped into five categor