Functional grading of mineral and collagen in the attachment of tendon to bone.
Ontology highlight
ABSTRACT: Attachment of dissimilar materials is a major challenge because high levels of localized stress may develop at their interfaces. An effective biologic solution to this problem exists at one of nature's most extreme interfaces: the attachment of tendon (a compliant, structural "soft tissue") to bone (a stiff, structural "hard tissue"). The goal of our study was to develop biomechanical models to describe how the tendon-to-bone insertion derives its mechanical properties. We examined the tendon-to-bone insertion and found two factors that give the tendon-to-bone transition a unique grading in mechanical properties: 1), a gradation in mineral concentration, measured by Raman spectroscopy; and 2), a gradation in collagen fiber orientation, measured by polarized light microscopy. Our measuremen
SUBMITTER: Genin GM
PROVIDER: S-EPMC2726319 | biostudies-literature | 2009 Aug
REPOSITORIES: biostudies-literature
ACCESS DATA