Ontology highlight
ABSTRACT: Background
Computed tomography (CT) lung densitometry has been demonstrated to be the most sensitive and specific outcome measure for the assessment of emphysema-modifying therapy, but the optimum densitometric index has yet to be determined and targeted sampling may be more sensitive than whole lung assessment. The EXAcerbations and CT scan as Lung Endpoints (EXACTLE) trial aimed to clarify the optimum approach to the use of CT densitometry data for the assessment of alpha 1-antitrypsin (AAT) augmentation therapy on the progression of emphysema in AAT deficiency (AATD).Methods
Patients with AATD (n = 77) were randomised to weekly infusions of 60 mg/kg human AAT (Prolastin) or placebo over 2 to 2.5 years. Lung volume was included as a covariate in an endpoint analysis and a
SUBMITTER: Parr DG
PROVIDER: S-EPMC2740846 | biostudies-literature | 2009 Aug
REPOSITORIES: biostudies-literature