Purification of hemoglobin by tangential flow filtration with diafiltration.
Ontology highlight
ABSTRACT: A recent study by Palmer, Sun, and Harris (Biotechnol. Prog., 25:189-199, 2009) demonstrated that tangential flow filtration (TFF) can be used to produce HPLC-grade bovine and human hemoglobin (Hb). In this current study, we assessed the quality of bovine Hb (bHb) purified by introducing a 10 L batch-mode diafiltration step to the previously mentioned TFF Hb purification process. The bHb was purified from bovine red blood cells (RBCs) by filtering clarified RBC lysate through 50 nm (stage I) and 500 kDa (stage II) hollow fiber (HF) membranes. The filtrate was then passed through a 100 kDa (stage III) HF membrane with or without an additional 10 L diafiltration step to potentially remove additional small molecular weight impurities. Protein assays, SDS-PAGE, and LC-MS of the purified bHb (s
SUBMITTER: Elmer J
PROVIDER: S-EPMC2783993 | biostudies-literature | 2009 Sep-Oct
REPOSITORIES: biostudies-literature
ACCESS DATA