Ontology highlight
ABSTRACT: Objective
Continuous glucose monitoring (CGM) has been found to improve glucose control in type 1 diabetic patients. We estimated the cost-effectiveness of CGM versus standard glucose monitoring in type 1 diabetes. RESEARCH DESIGN AND METHODS This societal cost-effectiveness analysis (CEA) was conducted in trial populations in which CGM has produced a significant glycemic benefit (A1C >or=7.0% in a cohort of adults aged >or=25 years and A1C <7.0% in a cohort of all ages). Trial data were integrated into a simulation model of type 1 diabetes complications. The main outcome was the cost per quality-adjusted life-year (QALY) gained.Results
During the trials, CGM patients experienced an immediate quality-of-life benefit (A1C >or=7.0% cohort: 0.70 quality-adjusted life-weeks [QA
SUBMITTER: Huang ES
PROVIDER: S-EPMC2875436 | biostudies-literature | 2010 Jun
REPOSITORIES: biostudies-literature