Project description:Top down proteomics in a TOF-TOF instrument was further explored by examining the fragmentation of multiply charged precursors ions generated by matrix-assisted laser desorption ionization. Evaluation of sample preparation conditions allowed selection of solvent/matrix conditions and sample deposition methods to produce sufficiently abundant doubly and triply charged precursor ions for subsequent CID experiments. As previously reported, preferential cleavage was observed at sites C-terminal to acidic residues and N-terminal to proline residues for all ions examined. An increase in nonpreferential fragmentation as well as additional low mass product ions was observed in the spectra from multiply charged precursor ions providing increased sequence coverage. This enhanced fragmentation from multiply charged precursor ions became increasingly important with increasing protein molecular weight and facilitates protein identification using database searching algorithms. The useable mass range for MALDI TOF-TOF analysis of intact proteins has been expanded to 18.2 kDa using this approach.
Project description:Matrix-Assisted Laser Desorption/Ionization Time Of Flight Mass Spectrometry (MALDI-TOF MS) technology is currently increasingly used in diagnostic laboratories as a cost effective, rapid and reliable routine technique for the identification and typing of microorganisms. In this study, we used MALDI-TOF MS to analyze a collection of 160 strains belonging to the Bacillus cereus group (57 B. anthracis, 49 B. cereus, 1 B. mycoides, 18 B. wiedmannii, 27 B. thuringiensis, 7 B. toyonensis and 1 B. weihenstephanensis) and to detect specific biomarkers which would allow an unequivocal identification. The Main Spectra Profiles (MSPs) were added to an in-house reference library, expanding the current commercial library which does not include B. toyonensis and B. wiedmannii mass spectra. The obtained mass spectra were statistically compared by Principal Component Analysis (PCA) that revealed seven different clusters. Moreover, for the identification purpose, were generated dedicate algorithms for a rapid and automatic detection of characteristic ion peaks after the mass spectra acquisition. The presence of specific biomarkers can be used to differentiate strains within the B. cereus group and to make a reliable identification of Bacillus anthracis, etiologic agent of anthrax, which is the most pathogenic and feared bacterium of the group. This could offer a critical time advantage for the diagnosis and for the clinical management of human anthrax even in case of bioterror attacks.
Project description:In recent years, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) plays an essential role in the analysis of polymers. To acquire a more reliable strategy for polymer profiling, we characterized four representative polymers including polyethylene glycol 6000, polyvinylpyrrolidone K12, polymer polyol KPOP-5040, and polyether polyol DL-4000. The preparation methods of these four polymer samples have been optimized from six aspects, including matrix, cationization reagent, solvent, mixing ratio of cationization reagent to polymer, mixing ratio of matrix to polymer, and laser intensity. After investigating the effects of seven commonly used matrices on the ionization efficiency of four polymers, trans-2-[3-(4-tert-butylphenyl)-2-methyl-2-propenylidene] malononitrile (DCTB) was found to be the only matrix suitable for the analysis of all the four polymers. Our experimental results suggested that different polymers showed a certain preference for different cationization reagents. For example, the polymer polyol KPOP-5040 was suitable for sodium iodide as the cationization reagent, while polyvinylpyrrolidone K12 was more suitable for silver trifluoroacetate (AgTFA). For the choice of solvent, tetrahydrofuran is a reagent with rapid evaporation and a wide range of dissolution which can achieve the best results for the analysis of four polymers. The optimized method was successfully applied to the identification of DSPE-PEG-NH2 with different polymerized degrees. This MALDI-TOF strategy potentially provided the supplementary function through the polymer's application in biomedical and visible probing.
Project description:BackgroundAn accurate and timely identification of bacterial species is critical in clinical diagnostics. Species identification allows a potential first adaptation of empiric antibiotic treatments before the resistance profile is available. Matrix assisted Laser Desorption Ionization Time of Flight mass spectrometry (MALDI-TOF MS) is a widely used method for bacterial species identification. However, important challenges in species identification remain. These arise from (i) incomplete databases, (ii) close relatedness of species of interest, and (iii) spectral quality, which is currently vaguely defined.MethodsWe selected 47 clinically relevant bacterial isolates from 39 species, which can be challenging to identify by MALDI-TOF MS. We measured these isolates under various analytical conditions on two MALDI-TOF MS systems. First, we identified spectral features, which were associated with correct species identification in three different databases. Considering these features, we then systematically compared spectra produced with three different sample preparation protocols. In addition, we varied quantities of bacterial colony material applied and bacterial colony age.ResultsWe identified (i) the number of ribosomal marker peaks detected, (ii) the median relative intensity of ribosomal marker peaks, (iii) the sum of the intensity of all detected peaks, (iv) a high measurement precision, and (v) reproducibility of peaks to act as good proxies of spectral quality. We found that using formic acid, measuring bacterial colonies at a young age, and frequently calibrating the MALDI-TOF MS device increase mass spectral quality. We further observed significant differences in spectral quality between different bacterial taxa and optimal measurement conditions vary per taxon.ConclusionWe identified and applied quality measures for MALDI-TOF MS and optimized spectral quality in routine settings. Phylogenetic marker peaks can be reproducibly detected and provide an increased resolution and the ability to distinguish between challenging species such as those within the Enterobacter cloacae complex, Burkholderia cepacia complex, or viridans streptococci.
Project description:Synthetic siRNA duplexes are used widely as reagents for silencing of mRNA targets in cells and are being developed for in vivo use. Serum stability is a major concern if siRNA is to be used for therapeutic delivery within blood circulation. We have developed the use of MALDI-TOF mass spectrometry as a rapid and convenient analytical tool to identify the most vulnerable sites within siRNA to serum degradation. Using this approach, we found that one siRNA duplex (Dh3) with UpA sequences close to one end was particularly vulnerable to rapid cleavage. This produced a fragment of mass consistent with the presence of a 2',3'-cyclic phosphate that was slowly hydrolysed to a 2'-(3'-)phosphate on extended incubation. Substitution of these sites with 2'-O-methyl U residues prevented cleavage and confirmed that the major pathway for initial degradation is via cleavage by an RNAse A-like activity. Mass spectral analysis was used to follow the serum degradation of siRNA over more prolonged periods to show the accumulation of many fragments, almost all showing cleavage following pyrimidine nucleoside residues. Overall, the MALDI-TOF mass spectral analysis technique should prove useful for preliminary screening of the serum stability of siRNA duplexes and for identification of the most vulnerable cleavage sites.
Project description:Viridans Group Streptococci (VGS) species-level identification is fundamental for patients management. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been used for VGS identification but discrimination within the Mitis group resulted difficult. In this study, VGS identifications with two MALDI-TOF instruments, the Biotyper (Bruker) and the VITEK MS (bioMérieux) have been compared to those derived from tuf, soda and rpoB genes sequencing. VGS isolates were clustered and a dendrogram constructed using the Biotyper 3.0 software (Bruker). RpoB gene sequencing resulted the most sensitive and specific molecular method for S. pneumonia identification and was used as reference method. The sensitivity and the specificity of the VITEK MS in S. pneumonia identification were 100%, while the Biotyper resulted less specific (92.4%). In non pneumococcal VGS strains, the group-level correlation between rpoB and the Biotyper was 100%, while the species-level correlation was 61% after database upgrading (than 37% before upgrading). The group-level correlation between rpoB and the VITEK MS was 100%, while the species-level correlation was 36% and increases at 69% if isolates identified as S. mitis/S. oralis are included. The less accurate performance of the VITEK MS in VGS identification within the Mitis group was due to the inability to discriminate between S. mitis and S. oralis. Conversely, the Biotyper, after the release of the upgraded database, was able to discriminate between the two species. In the dendrogram, VGS strains from the same group were grouped into the same cluster and had a good correspondence with the gene-based clustering reported by other authors, thus confirming the validity of the upgraded version of the database. Data from this study demonstrated that MALDI-TOF technique can represent a rapid and cost saving method for VGS identification even within the Mitis group but improvements of spectra database are still recommended.
Project description:Although procyanidins constitute a unique class of polymeric plant secondary metabolites with a variety of biological properties including potent antioxidant activity, structure determination has been challenging, and structures of many complex procyanidins remain uncertain. To expedite the characterization of procyanidins, negative ion matrix-assisted laser desorption ionization high-energy collision-induced dissociation tandem time-of-flight (MALDI-ToF/ToF) mass spectra of 20 isolated procyanidins containing catechin and epicatechin subunits with degrees of polymerization up to five were obtained and evaluated. Structurally significant fragmentation pathways of singly charged, deprotonated molecules were identified representing quinone methide, heterocyclic ring fission, and retro-Diels-Alder fragmentation. The interpretation of the tandem mass spectra for sequencing A-type, B-type, mixed-type, linear, and branched procyanidins is explained using specific examples of each.
Project description:BackgroundOligosaccharidoses, which belong to the lysosomal storage diseases, are inherited metabolic disorders due to the absence or the loss of function of one of the enzymes involved in the catabolic pathway of glycoproteins and indirectly of glycosphingolipids. This enzymatic deficiency typically results in the abnormal accumulation of uncompletely degraded oligosaccharides in the urine. Since the clinical features of many of these disorders are not specific for a single enzyme deficiency, unambiguous screening is critical to limit the number of costly enzyme assays which otherwise must be performed.MethodsHere we provide evidence for the advantages of using a MALDI-TOF/TOF (matrix-assisted laser desorption ionization time-of-flight) mass spectrometric (MS) method for screening oligosaccharidoses. Urine samples from previously diagnosed patients or from unaffected subjects were randomly divided into a training set and a blind testing set. Samples were directly analyzed without prior treatment.ResultsThe characteristic MS and MS/MS molecular profiles obtained allowed us to identify fucosidosis, aspartylglucosaminuria, GM1 gangliosidosis, Sandhoff disease, α-mannosidosis, sialidosis and mucolipidoses type II and III.ConclusionsThis method, which is easily run in less than 30 minutes, is performed in a single step, and is sensitive and specific. Invaluable for clinical chemistry purposes this MALDI-TOF/TOF mass spectrometry procedure is semi-automatizable and suitable for the urinary screening of oligosacharidoses.
Project description:The insufficient quality of products containing beneficial live bacteria in terms of content and viability of labelled microorganisms is an often-reported problem. The aim of this work was to evaluate the quality of dietary supplements containing viable bacteria available in Slovenian pharmacies using plate counting, matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF MS) and species- or subspecies-specific PCR with DNA isolated from consortia of viable bacteria, from individual isolates, or directly from the products. Twelve percent of the products (3 of 26) contained insufficient numbers of viable bacteria. Eighty-three of the labelled species (111 in total) were confirmed by PCR with DNA from the product; 74% of these were confirmed by PCR with DNA from viable consortium, and 65% of these were confirmed by MALDI-TOF MS analysis of colonies. Certain species in multi-strain products were confirmed by PCR with DNA from viable consortia but not by MALDI-TOF MS, suggesting that the number of isolates examined (three per labelled strain) was too low. With the exception of Lacticaseibacillus casei and closely related species (Lacticaseibacillus rhamnosus and Lacticaseibacillus zeae), PCR and MALDI-TOF identification results agreed for 99% of the isolates examined, although several MALDI-TOF results had lower score values (1.700-1.999), indicating that the species identification was not reliable. The species L. zeae, which appeared in 20 matches of the Biotyper analysis, was identified as L. rhamnosus by PCR. The MALDI-TOF MS analysis was also unsuccessful in detecting Lactobacillus acidophilus La-5 and Bacillus coagulans due to missing peaks and unreliable identification, respectively. Mislabelling was detected by both methods for two putative L. casei strains that turned out to belong to the species Lacticaseibacillus paracasei. PCR remains more successful in subspecies-level identification as long as the database of MALDI-TOF MS spectra is not expanded by building in-house databases. The lack of positive PCR results with viable consortia or colonies, but positive PCR results with DNA isolated directly from the products observed in 10% (11/112) of the labelled strains, suggests the presence of non-culturable bacteria in the products. MALDI-TOF MS is a faster and simpler alternative to PCR identification, provided that a sufficient number of colonies are examined. Generation of in-house library may further improve the identification accuracy at the species and sub-species level.
Project description:The identification of proteins by tandem mass spectrometry relies on knowledge of the products produced by collision-induced dissociation of peptide ions. Most previous work has focused on fragmentation statistics for ion trap systems. We analyzed fragmentation in MALDI TOF/TOF mass spectrometry, collecting statistics using a curated set of 2459 MS/MS spectra and applying bootstrap resampling to assess confidence intervals. We calculated the frequency of 18 product ion types, the correlation between both mass and intensity with ion type, the dependence of amide bond breakage on the residues surrounding the cleavage site, and the dependence of product ion detection on residues not adjacent to the cleavage site. The most frequently observed were internal ions, followed by y ions. A strong correlation between ion type and the mass and intensity of its peak was observed, with b and y ions producing the most intense and highest mass peaks. The amino acids P, W, D, and R had a strong effect on amide bond cleavage when situated next to the breakage site, whereas residues including I, K, and H had a strong effect on product ion observation when located in the peptide but not adjacent to the cleavage site, a novel observation.