Unknown

Dataset Information

Determination of serum and plasma sclerostin concentrations by enzyme-linked immunoassays.


ABSTRACT:

Background

Sclerostin alters bone formation. The precise and reproducible measurement of sclerostin concentrations in biological samples is important for assessment of metabolic bone disease. We determined sclerostin concentrations in serum and plasma using two commercially available ELISA.

Methods

We measured sclerostin concentrations in serum or heparin-plasma obtained from 25 normal human subjects using two commercial ELISA available from Biomedica Medizinprodukte GmbH and TECOmedical AG.

Results

With the Biomedica assay, serum sclerostin concentrations were 0.99 ± 0.12 ng/ml (mean ± sem), and plasma concentrations were 1.47 ± 0.13 ng/ml (paired t test, P < 0.001). With the TECO assay, serum sclerostin levels were 0.71 ± 0.05 ng/ml, and plasma sclerostin concentrat

SUBMITTER: McNulty M 

PROVIDER: S-EPMC3135202 | biostudies-literature | 2011 Jul

REPOSITORIES: biostudies-literature