Unknown

Dataset Information

Reduction of blood loss in primary hip arthroplasty with tranexamic acid or fibrin spray.


ABSTRACT:

Background and purpose

Previous studies have shown that either fibrin spray or tranexamic acid can reduce blood loss at total hip replacement, but the 2 treatments have not been directly compared. We therefore conducted a randomized, controlled trial.

Patients and methods

In this randomized controlled trial we compared the effect of tranexamic acid and fibrin spray on blood loss in cemented total hip arthroplasty. 66 patients were randomized to 1 of 3 parallel groups receiving (1) a 10 mg/kg bolus of tranexamic acid prior to surgery, (2) 10 mL of fibrin spray during surgery, or (3) neither. All participants except the surgeon were blinded as to treatment group until data analysis was complete. Blood loss was calculated from preoperative and postoperative hematocrit.

Resul

SUBMITTER: McConnell JS 

PROVIDER: S-EPMC3247881 | biostudies-literature | 2011 Dec

REPOSITORIES: biostudies-literature