Unknown

Dataset Information

Prostate bed motion during intensity-modulated radiotherapy treatment.


ABSTRACT:

Purpose

Conformal radiation therapy in the postprostatectomy setting requires accurate setup and localization of the prostatic fossa. In this series, we report prostate bed localization and motion characteristics, using data collected from implanted radiofrequency transponders.

Methods and materials

The Calypso four-dimensional localization system uses three implanted radiofrequency transponders for daily target localization and real-time tracking throughout a course of radiation therapy. We reviewed the localization and tracking reports for 20 patients who received ultrasonography-guided placement of Calypso transponders within the prostate bed prior to a course of intensity-modulated radiation therapy at Fox Chase Cancer Center.

Results

At localization, prostate bed

SUBMITTER: Klayton T 

PROVIDER: S-EPMC3285397 | biostudies-literature | 2012 Sep

REPOSITORIES: biostudies-literature