Ontology highlight
ABSTRACT: Background
Interscalene block (ISB) is commonly performed using 20-40 mL of local anesthetic. Spread to adjacent structures and consequent adverse effects including paralysis of the ipsilateral hemidiaphragm are frequent. Pain ratings, analgesic requirements, adverse events, satisfaction, function and diaphragmatic excursion were compared following interscalene block (ISB) with reduced initial bolus volumes.Methods
Subjects undergoing arthroscopic rotator cuff repair were randomized to receive 5, 10, or 20 mL ropivacaine 0.75% for ISB in a double-blind fashion (N = 36). Continuous infusion with ropivacaine 0.2% was maintained for 48 h. Pain and diaphragmatic excursion were assessed before block and in the recovery unit.Results
Pain ratings in the recovery room were generally less than 4 (0-10 NRS) for all treatment groups, but a statistically significant difference was noted between the 5 and 20 mL groups (NRS: 2.67 vs. 0.62 respectively; p = 0.04). Pain ratings and supplemental analgesic use were similar among the groups at 24 h, 48 h and 12 weeks. There were no differences in the quality of block for surgical anesthesia. Dyspnea was significantly greater in the 20 mL group (p = 0.041). Subjects with dyspnea had significant diaphragmatic impairment more frequently (Relative risk: 2.5; 95%CI: 1.3-4.8; p = 0.042). Increased contralateral diaphragmatic motion was measured in 29 of the 36 subjects. Physical shoulder function at 12 weeks improved over baseline in all groups (baseline mean SST: 6.3, SEM: 0.6; 95%CI: 5.1-7.5; 12 week mean SST: 8.2, SEM: 0.46; 95%CI: 7.3-9.2; p = 0.0035).Conclusions
ISB provided reliable surgical analgesia with 5 mL, 10 mL or 20 mL ropivacaine (0.75%). The 20 mL volume was associated with increased complaints of dyspnea. The 5 mL volume was associated with statistically higher pain scores in the immediate postoperative period. Lower volumes resulted in a reduced incidence of dyspnea compared to 20 mL, however diaphragmatic impairment was not eliminated. Compensatory increases in contralateral diaphragmatic movement may explain tolerance for ipsilateral paresis.Trial registration
clinicaltrials.gov. identifier: NCT00672100.
SUBMITTER: Hartrick CT
PROVIDER: S-EPMC3348027 | biostudies-literature | 2012 Mar
REPOSITORIES: biostudies-literature

Hartrick Craig T CT Tang Yeong-Shih YS Siwek Don D Murray Robert R Hunstad David D Smith Greg G
BMC anesthesiology 20120323
<h4>Background</h4>Interscalene block (ISB) is commonly performed using 20-40 mL of local anesthetic. Spread to adjacent structures and consequent adverse effects including paralysis of the ipsilateral hemidiaphragm are frequent. Pain ratings, analgesic requirements, adverse events, satisfaction, function and diaphragmatic excursion were compared following interscalene block (ISB) with reduced initial bolus volumes.<h4>Methods</h4>Subjects undergoing arthroscopic rotator cuff repair were randomi ...[more]