Ontology highlight
ABSTRACT: Background
Recently developed detection system for circulating tumour cells (CTCs) using a telomerase-specific replicative adenovirus generated nonspecific green fluorescent protein (GFP) signals because of the co-presence of white blood cells (WBCs) nonspecifically infected by viruses. Here, we established a unique detection system for CTCs that completely excludes nonspecific signals.Methods
Blood obtained from the patients was subjected to haemolytic processes to eliminate red blood cells. The cell pellets were then infected with OBP-401, fixed, incubated with fluorescence-labelled anti-CD45 antibody to mark white blood WBCs, and examined on slides under a microscope.Results
Preparatory experiments with cancer cells artificially added to healthy donor samples con
SUBMITTER: Takakura M
PROVIDER: S-EPMC3405215 | biostudies-literature | 2012 Jul