Evaluation of Airborne Particle Emissions from Commercial Products Containing Carbon Nanotubes.
Ontology highlight
ABSTRACT: The emission of the airborne particles from epoxy resin test sticks with different CNT loadings and two commercial products were characterized while sanding with three grit sizes and three disc sander speeds. The total number concentrations, respirable mass concentrations, and particle size number/mass distributions of the emitted particles were measured using a condensation particle counter, an optical particle counter, and a scanning mobility particle sizer. The emitted particles were sampled on a polycarbonate filter and analyzed using electron microscopy. The highest number concentrations (arithmetic mean = 4670 particles/cm(3)) were produced with coarse sandpaper, 2% (by weight) CNT test sticks and medium disc sander speed, whereas the lowest number concentrations (arithmetic mean = 9
SUBMITTER: Huang G
PROVIDER: S-EPMC3507461 | biostudies-literature | 2012 Oct
REPOSITORIES: biostudies-literature